Free NCP-ARI Practice Questions

Explore 9 free practice questions for the NVIDIA NCP-ARI exam and review the answers and explanations to support your preparation.

  1. Question 1

    Single answer

    Above the audited rows, inter-rack bundles span up to 1.5 m between overhead support points and sag

    visibly at mid-span, and freshly landed bundles hang loose for their first couple of meters before entering

    the rack's cable management hardware. Which guideline pair applies to these findings?


    • Option A:

      Support cables at least every two feet (60 cm) along the run, and guide a bundle's first 8 feet into management. 

      Correct
    • Option B:

      Support spacing scales with bundle weight, so fiber-only spans may run 2 m between points if sag stays under 10 cm.

      Correct
    • Option C:

      The sag is acceptable while jacket tension stays low; the true defect is only the unguided tails at the rack entries.

      Correct
    • Option D:

      Support cables at least every meter along the run, and guide a bundle's first 3 feet into management hardware

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: A

    Explanation

    Cable bundles should receive frequent mechanical support to prevent sag and excessive strain. The

    guidance calls for support approximately every 60 cm and for the first 8 feet of an arriving bundle to be

    guided into cable-management hardware.

  2. Question 2

    Single answer

    A technician must verify phase balance at an energized 415 V three-phase remote power panel serving

    the expansion row. The panel carries an arc flash label from last year's incident energy study, and the

    hall's PPE locker stocks several categories of gear. What governs what the technician wears and where

    he stands?

    • Option A:

      Arc flash controls begin above 600 V, so a 415 V panel calls for shock PPE and insulated tools by themselves. 

      Correct
    • Option B:

      The label's incident energy and arc flash boundary set the PPE category and the standoff for this task

      Correct
    • Option C:

      The boundary takes effect once covers come off, so closed-door verification needs standard gloves at most. 

      Correct
    • Option D:

      A category 2, 8 cal per cm2 kit covers data center panels, which fall below the study's analysis threshold.

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: B

    Explanation

    The arc flash label provides the incident-energy information and defined arc flash boundary for the

    equipment. These values determine the required PPE and the safe working distance for the specific

    task.

  3. Question 3

    Single answer

    Floor planning for the retrofit shows the replacement AI racks are wider than the 600 mm cabinets they

    displace, which breaks the room's tile-aligned row pitch. A stakeholder asks what the extra width actually

    buys before approving the disruptive new layout. Which explanation is accurate?


    • Option A:

      The added width forms a side air plenum letting the rack draw intake air laterally when containment doors restrict frontal airflow.

      Correct
    • Option B:

      The added width creates side volume for vertical cable management, power delivery hardware, and liquid manifolds beside the equipment rails.

      Correct
    • Option C:

      The added width lets two half-width compute nodes mount side by side per U, doubling density without changing the rack height budget. 

      Correct
    • Option D:

      The added width spreads the rack's mass across more floor tiles, bringing point loading back within standard raised-floor tile ratings.

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: B

    Explanation

    The additional rack width provides valuable side space beside the equipment rails. This space supports

    vertical cable management, power-delivery components, and liquid-cooling manifolds required by dense

    AI infrastructure.

  4. Question 4

    Single answer

    A colocation provider preparing whips for an incoming GB200 NVL72 rack asks whether the tenant

    needs the facility's negative 48 V DC plant, since the rack is advertised as using DC busbar power

    distribution to its compute trays. How should the deployment technician explain the rack's actual input

    requirement?


    • Option A:

      The rack needs the facility DC plant, because the NVLink cartridge backplane is fed straight from

      the busbar and cannot tolerate rectifier ripple at full load.

      Correct
    • Option B:

      The rack needs AC only for its fans and management plane, while the compute trays pull their main

      load from the facility's separate DC distribution plant.


      Correct
    • Option C:

      The rack accepts either AC whips or the 48 V plant, because its power shelves auto-range between

      rectifier duty and a direct DC pass-through operating mode.


      Correct
    • Option D:

      The rack takes standard three-phase AC whips; its internal power shelves rectify that input and

      energize the DC busbar that serves the compute trays.

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: D

    Explanation

    The GB200 NVL72 rack receives standard three-phase AC power from the facility. Internal power

    shelves convert the AC input to DC and supply the rack's DC busbar, which then distributes power to the

    compute trays.

  5. Question 5

    Single answer

    An administrator needs to search for an available NAI helm chart version.Which command should the administrator use?

    • Option A:

      helm pull ntnx-charts/nai-core --versions

      Correct
    • Option B:

      helm repo list ntnx-charts/nai-core

      Correct
    • Option C:

      helm search repo ntnx-charts/nai-core --versions

      Correct
    • Option D:

      helm repo get ntnx-charts –versions

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: C

  6. Question 6

    Multiple answers

    An administrator is setting up Nutanix Enterprise AI with a custom domain (ai.company.com) and must comply with security policies requiring a valid TLS certificate from the corporate certificate authority (CA).Which two steps are necessary to complete this configuration successfully? (Choose two.)

    • Option A:

      Add a DNS A record pointing ai.company.com to the NAI IP address in a DNS server

      Correct
    • Option B:

      Create a DNS PTR record for ai.company.com to match the DNS A recorD

      Correct
    • Option C:

      A CA signed TLS certificate for the configured NAI FQDN

      Correct
    • Option D:

      Use the Nutanix Prism interface to directly assign the FQDN ai.company.com to the NAI IPaddress.

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: A, C

  7. Question 7

    Single answer

    An administrator is integrating an application with an endpoint and finds that the application isexperiencing high latency.What action should the administrator take to ensure the lowest latency when creating endpoints?

    • Option A:

      Reduce the payload size limit

      Correct
    • Option B:

      Increase the timeout value on the endpoints

      Correct
    • Option C:

      Increase the cache expiration time.

      Correct
    • Option D:

      Increase the number of endpoint instances.

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: D

  8. Question 8

    Single answer

    An administrator is setting up Nutanix AI to support generative AI use cases and needs to makea Large Language Model (LLM) available within the platform.Which action must the administrator perform?

    • Option A:

      Upload the LLM through the Nutanix AI portal's model import interface

      Correct
    • Option B:

      Enable LLM auto-discovery in the cluster settings

      Correct
    • Option C:

      Deploy the LLM using a third-party container orchestration tool

      Correct
    • Option D:

       Install the LLM using the Nutanix Prism Central marketplace

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: A

  9. Question 9

    Single answer

    Which Nutanix AI deployment platform is supported?


    • Option A:

      Native Kubernetes

      Correct
    • Option B:

      AWS EC2

      Correct
    • Option C:

      Nutanix NKE

      Correct
    • Option D:

      On-premises NCI

      Correct
    Show Answer & Explanation Hide Answer & Explanation

    Correct Answer: C